Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1 The fire in Oxygen Tank 2 blew out the aluminum exterior panel covering Sector 4 of the service module, exposing the sector to space and snuffing out the fire.1 The switches in Oxygen Tank 2 could fail at the 65 volts used during ground testing at KSC, although they were designed for the command module's 28-volt power.1

A summary made of Oxygen Tank 2's own facts, quoted as read; each sentence cites its source.

Connections

2 linked subjects · 1 link inferred · 8 named together

A link reads subject → relation → subject. Each is stated by a fact (quoted, with its source), taken from Wikidata, or worked out by the knowledge graph's reasoner from the links it was given; inferred links are marked ∴ with the rule behind them.

Oxygen Tank 2 and 10 of its closest connectionsPolytetrafluoroethylene · named together · Apollo 13Polytetrafluoroethylene · named together · Apollo 13 review boardApollo 13 · crew members · Jim LovellApollo 13 · named together · Apollo 10Apollo 13 · crew members · Jack SwigertApollo 13 · crew members · Ken MattinglyApollo 13 · named together · Apollo 13 review boardJim Lovell · named together · Jack SwigertJim Lovell · named together · Ken MattinglyJack Swigert · succeeded in role · Ken MattinglyPolytetrafluoroet…BeechcraftApollo 13Jim LovellApollo 10Jack SwigertKen MattinglyRockwell Interna…Apollo 13 review…Terminal countdow…
Point at a subject to see how it links to Oxygen Tank 2.
  • stated
  • inferred
  • named together
  • Polytetrafluoroethylene Concept
    • (Oxygen Tank 2 → has part(s) → Polytetrafluoroethylene) Temperatures on the heater tube inside Oxygen Tank 2 may have reached 540 °C (1,000 °F), most likely damaging the Teflon insulation.1
    • (Polytetrafluoroethylene → part of → Oxygen Tank 2) inferred: the other reading of “has part(s)” (above)
  • Beechcraft Organization
    • (Beechcraft → product or material produced → Oxygen Tank 2) Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1

Named together

Subjects that share a fact with Oxygen Tank 2, with no typed link between them yet.

  • Apollo 13 1 shared fact
    • The shelf containing Oxygen Tank 2 was re-installed in SM-109, intended for Apollo 13, in November 1968.1
  • Jim Lovell 1 shared fact
    • The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1
  • Apollo 10 1 shared fact
    • During removal from the Apollo 10 service module SM-106, the oxygen shelf holding Oxygen Tank 2 was accidentally dropped at least 5 centimeters because a retaining bolt had not been removed.1
  • Jack Swigert 1 shared fact
    • The review board found that Swigert's activation of the Oxygen Tank 2 fan at Mission Control's request caused an electric arc that set the tank on fire.1
  • Ken Mattingly 1 shared fact
    • The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1
  • Rockwell International 1 shared fact
    • Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1
  • Apollo 13 review board 2 shared facts
    • The review board's report questioned the use of Teflon and aluminum, materials shown to be flammable in supercritical oxygen, within the oxygen tank.1
  • Terminal countdown demonstration test 1 shared fact
    • During the Countdown Demonstration Test, which began on March 16, 1970, Oxygen Tank 2 could not be emptied through the normal drain line.1

Oxygen Tank 2: facts

13 facts in 3 categories · rated most surprising

Making and creation (2 facts)

  • Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1
  • The shelf containing Oxygen Tank 2 was re-installed in SM-109, intended for Apollo 13, in November 1968.1

Events (8 facts)

  • The fire in Oxygen Tank 2 blew out the aluminum exterior panel covering Sector 4 of the service module, exposing the sector to space and snuffing out the fire.1
  • During removal from the Apollo 10 service module SM-106, the oxygen shelf holding Oxygen Tank 2 was accidentally dropped at least 5 centimeters because a retaining bolt had not been removed.1
  • During the Countdown Demonstration Test, which began on March 16, 1970, Oxygen Tank 2 could not be emptied through the normal drain line.1
  • Temperatures on the heater tube inside Oxygen Tank 2 may have reached 540 °C (1,000 °F), most likely damaging the Teflon insulation.1
  • The review board found that Swigert's activation of the Oxygen Tank 2 fan at Mission Control's request caused an electric arc that set the tank on fire.1
  • Damaged Teflon insulation on wires to the stirring fan inside Oxygen Tank 2 let the wires short circuit and ignite the insulation.1
  • The heaters in Oxygen Tank 2 were turned on to boil off oxygen when it would not empty normally.1
  • The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1

Details and parts (3 facts)

  • The switches in Oxygen Tank 2 could fail at the 65 volts used during ground testing at KSC, although they were designed for the command module's 28-volt power.1
  • The thermostatic switches were designed to keep the tank heaters below 27 °C (80 °F) but failed under the 65-volt supply.1
  • The temperature gauge in Oxygen Tank 2 was not designed to read above 29 °C (85 °F), so the monitoring technician detected nothing unusual.1

Mentioned on other pages

3 facts about other subjects name Oxygen Tank 2

  • Apollo 13 review board: The review board's report questioned the use of Teflon and aluminum, materials shown to be flammable in supercritical oxygen, within the oxygen tank.1
  • Beechcraft: The thermostatic switches Beech used in Oxygen Tank 2 were not rated for 65 volts.1
  • Apollo 13 review board: In a board test, an oxygen tank rigged with hot-wire ignitors heated rapidly, then failed, producing telemetry similar to that of Oxygen Tank 2 on Apollo 13.1