Oxygen Tank 2
Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1 The fire in Oxygen Tank 2 blew out the aluminum exterior panel covering Sector 4 of the service module, exposing the sector to space and snuffing out the fire.1 The switches in Oxygen Tank 2 could fail at the 65 volts used during ground testing at KSC, although they were designed for the command module's 28-volt power.1
A summary made of Oxygen Tank 2's own facts, quoted as read; each sentence cites its source.
Connections
2 linked subjects · 1 link inferred · 8 named together
A link reads subject → relation → subject. Each is stated by a fact (quoted, with its source), taken from Wikidata, or worked out by the knowledge graph's reasoner from the links it was given; inferred links are marked ∴ with the rule behind them.
- stated
- inferred
- named together
- Polytetrafluoroethylene Concept
- (Oxygen Tank 2 → has part(s) → Polytetrafluoroethylene) Temperatures on the heater tube inside Oxygen Tank 2 may have reached 540 °C (1,000 °F), most likely damaging the Teflon insulation.1
- (Polytetrafluoroethylene → part of → Oxygen Tank 2) inferred: the other reading of “has part(s)” (above)
- Beechcraft Organization
- (Beechcraft → product or material produced → Oxygen Tank 2) Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1
Named together
Subjects that share a fact with Oxygen Tank 2, with no typed link between them yet.
- Apollo 13 1 shared fact
- The shelf containing Oxygen Tank 2 was re-installed in SM-109, intended for Apollo 13, in November 1968.1
- Jim Lovell 1 shared fact
- The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1
- Apollo 10 1 shared fact
- During removal from the Apollo 10 service module SM-106, the oxygen shelf holding Oxygen Tank 2 was accidentally dropped at least 5 centimeters because a retaining bolt had not been removed.1
- Jack Swigert 1 shared fact
- The review board found that Swigert's activation of the Oxygen Tank 2 fan at Mission Control's request caused an electric arc that set the tank on fire.1
- Ken Mattingly 1 shared fact
- The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1
- Rockwell International 1 shared fact
- Oxygen Tank 2 was manufactured by the Beech Aircraft Company of Boulder, Colorado, as subcontractor to North American Rockwell.1
- Apollo 13 review board 2 shared facts
- The review board's report questioned the use of Teflon and aluminum, materials shown to be flammable in supercritical oxygen, within the oxygen tank.1
- Terminal countdown demonstration test 1 shared fact
- During the Countdown Demonstration Test, which began on March 16, 1970, Oxygen Tank 2 could not be emptied through the normal drain line.1
Oxygen Tank 2: facts
13 facts in 3 categories · rated most surprising
Making and creation (2 facts)
Events (8 facts)
- The fire in Oxygen Tank 2 blew out the aluminum exterior panel covering Sector 4 of the service module, exposing the sector to space and snuffing out the fire.1
- During removal from the Apollo 10 service module SM-106, the oxygen shelf holding Oxygen Tank 2 was accidentally dropped at least 5 centimeters because a retaining bolt had not been removed.1
- During the Countdown Demonstration Test, which began on March 16, 1970, Oxygen Tank 2 could not be emptied through the normal drain line.1
- Temperatures on the heater tube inside Oxygen Tank 2 may have reached 540 °C (1,000 °F), most likely damaging the Teflon insulation.1
- The review board found that Swigert's activation of the Oxygen Tank 2 fan at Mission Control's request caused an electric arc that set the tank on fire.1
- Damaged Teflon insulation on wires to the stirring fan inside Oxygen Tank 2 let the wires short circuit and ignite the insulation.1
- The heaters in Oxygen Tank 2 were turned on to boil off oxygen when it would not empty normally.1
- The heating procedure in Oxygen Tank 2 was approved by Lovell and Mattingly of the prime crew, as well as by NASA managers and engineers.1
Details and parts (3 facts)
- The switches in Oxygen Tank 2 could fail at the 65 volts used during ground testing at KSC, although they were designed for the command module's 28-volt power.1
- The thermostatic switches were designed to keep the tank heaters below 27 °C (80 °F) but failed under the 65-volt supply.1
- The temperature gauge in Oxygen Tank 2 was not designed to read above 29 °C (85 °F), so the monitoring technician detected nothing unusual.1
Mentioned on other pages
3 facts about other subjects name Oxygen Tank 2
- Apollo 13 review board: The review board's report questioned the use of Teflon and aluminum, materials shown to be flammable in supercritical oxygen, within the oxygen tank.1
- Beechcraft: The thermostatic switches Beech used in Oxygen Tank 2 were not rated for 65 volts.1
- Apollo 13 review board: In a board test, an oxygen tank rigged with hot-wire ignitors heated rapidly, then failed, producing telemetry similar to that of Oxygen Tank 2 on Apollo 13.1